Test Range
|
0-1mm(0.05in) up to 0-20,000 mm(800 in.) in steel at 5930m/s (19455f/s)
|
Velocity
|
256 - 16000 m/s continuously variable.
|
Probe Zero
|
0 to 999.999 µs.
|
Delay
|
0-20,000m (800in) in steel at 5930m/s.
|
Gain
|
0 to 110dB adjustable in 0.1, 0.5, 1, 2, 6,14 and 20dB steps.
|
Test Modes
|
Pulse echo and transmit/receive. Single Crystal, Double Crystal and Pitch-Catch.
|
Damping
|
50 and 400 Ohm damping selectable.
|
Pulser
|
100-450V -ve spike and square wave. Pulse Width from 30nS to 2500nS. Rise/Fall times <5nS into 50R load. Tunable.
|
Active Edge TM
|
Unique Active Edge Mode for improved near-surface resolution.
|
P.R.F
|
Adjustable 5Hz to 5kHz. External sync also available.
|
Screen Update Rate
|
60 Hz
|
Rectification
|
RF, Full wave, +ve half-wave and -ve half-wave.
|
Frequency Range
|
8 selectable filter bands.
|
|
i) 100kHz - 500kHz ii) 200kHz - 800kHz
|
|
iii) 0.4MHz - 1.6MHz iv) 1.4MHz - 3MHz
|
|
v) 3MHz - 8MHz vi) 7MHz - 15MHz
|
|
vii) 9MHz - 21MHz viii) 1.6 MHz - 22 MHz (Wideband)
|
|
Additional tuned low frequency pre-amp with Dryscan option.
|
Display
|
Colour Transflective VGA (640 x 480) TFT
|
Display area
|
116.16 x 87.2 mm (4.57 x 3.43 in).
|
A-Scan Area
|
400 x 510 pixels (normal), 460 x 620 (FS).
|
Colours
|
9 colour options with variable brightness.
|
Zoom
|
Expands range and delay to cover the area set by Gate 1 start & width controls.
|
AGC
|
Automatic Gain Control automatically sets the signal in Gate 1 to a level between 10% and 90% FSH,
|
|
tolerance between 5% and 20%.
|
Measurement Modes
|
|
Mode 1
|
Signal monitor, Gate alarms can be active but no measurements are displayed.
|
Mode 2
|
Depth and amplitude of first signal in gate.
|
Mode 3
|
Echo-Echo distance measurements.
|
Mode 4
|
Trigonometric display of beam-path, surface distance (including X-offset) and depth of indication from the inspection surface together with echo amplitude. Curved surface correction canbe applied for convex and concave surfaces. Half-skip can be indicated on screen.
|
Mode 5
|
Gate to Gate distance measurement
|
Mode 6
|
Flank to Flank
|
Mode 7
|
Beam Angle, calculated from beampath, hole radius and hole centre depth
|